Kinetix 6500 fault codes - Oct 13, 2017 · The system consists of a 1756-L73S Version 20 Processor and a 1756-EN2TR/B Version 5.28. The network has powerflex 40Ps and 1734-AENTRs on it. The Kinetix modules are 2094-EN02D-M01-SO Version 2.18. It has one rack with 4 Axis. There are 7 powerFlex 40ps and 7 1734-AENTR racks on the this system.

 
Kinetix 6500 Servo Drives Firmware Revision 3.003 Known Anomalies Catalog Numbers 2094-EN02D-M01-S0, 2094-EN02D-M01-S1 Feedback faults may re-post after executing a Motion Axis Fault Reset (MAFR) instruction on an axis with an Endat 2.2 feedback device.. Navy chief results fy24

Integrated Axis Module Power Rail 5. Pivot module downward and align the guide pins on the power rail with the guide pin holes in the back of the module. Page 47 Mounting the Kinetix 6000 Drive System 6. Gently push the module against the power rail connectors and into the final mounting position. Kinetix 6500 Acceleration with MAG instruction A line in our plant has always had an issue where everytime the jar filler stops/restarts, it wastes 5-8 bottles because of underfills. FWIW, the...How to update firmware for my kinetix 6500 control module Hello guys, Our existing kinetix control module revision is 3.001 but now I want to replace the faulty controller by new revision 3.003.i fixed...2094-EN02D-M01-S1 Kinetix 6200 and Kinetix 6500 Safe Speed Monitoring Safety Reference Manual. Manual ... These tables list the faults, fault codes, and display text ... Literature Library | Rockwell Automation Manual Indicated the following: Safe FLT 03...MP OUT NN. Motion Power Output Fault. A fault has been detected on the motion power output circuitry. On Safe Torque Off (-SO) models, the sub code is defined as follows: 01: Gate power evaluation fault. 02: Gate enable evaluation fault.Sign in with your organizational account. User Account. PasswordThere are (36) Powerflex 70 EC drives and (10) 2904 Kinetix Servo drives on this network. [160 total connections] Occasionally, and becoming more frequent, we're having 4 of the axis fault on: Control Sync Fault and Module Connection Timeout Fault. Both faults are time stamped at the same time. The faults are on 4 out of the 10 axis in …These enhancements correspond to Kinetix 6500 drive firmware revisions when used with RSLogix 5000 software. Table 1 - Enhancements with Revision 2.013. Cat. No. Enhancement. 2094-EN02D-M01-S0 and 2094-EN02D-M01-S1. The drive can detect reversed wiring of the encoder's sine and cosine signals when running a commutation test.Understanding the Safe Torque-off Condition vs Drive Fault . . . . 13 Chapter 2 ... Kinetix 6000 Multi-axis Servo Drive User Manual, publication 2094-UM001 Detailed mounting, wiring, setup with RSLogix 5000 software, applying ... National Electrical Code, published by the National Fire Protection Association of Boston, MA An article on wire ...This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc. Try our online PLC Simulator- FREE.Click here now to try it.Summary of Contents for Allen-Bradley ControlLogix. Page 1 Reference Manual Integrated Motion on the EtherNet/IP Network ControlLogix, CompactLogix, Kinetix 350, Kinetix 5500, Kinetix 5700, Kinetix 6500, PowerFlex 527, PowerFlex 755... Page 2 Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE).May 26, 2013. #1. Hello, we currently have a Kinetix 6500 application with a Controllogix 72 series processor system. There are 7 Servo Drives connected in a linear topology to a 1756-EN2T (rev 4.3) module (Slot 2). In addition, there are 9 Powerflex 40 VFD's, 3 x FlexIO Enet modules, 1 x Generic Touch Screen, 1 x Murr Cube 20 on the Control ... When a fault is detected, the status indicator displays an E and a two-digit Table 81 - FLT Sxx Fault Codes (continued) Four-character Display Message. RSLogix 5000 Fault Message. Problem or Symptom. Potential Cause. ... (Kinetix 6500 drives only)Kinetix 6200 and Kinetix 6500 Modular Servo Drives Kinetix 6000 Drive Component Compatibility The 2094-BCxx-Mxx-M and 2094-BMxx-M power modules contain the same power structure as the 2094-BCxx-Mxx-S and 2094-BMxx-S drives. Because of this, the 2094-BSP2 shunt module, 2094-PRF slot-filler module, and 2094-PRS x power rails are allIf you own an AOTG24KMCA Fujitsu air conditioning unit, you may occasionally encounter fault codes that can disrupt its normal operation. These fault codes are designed to help ide... Kinetix 5700, Kinetix 6500, PowerFlex 527, PowerFlex 755 Integrated Motion on the EtherNet/IP Network 2 Rockwell Automation Publication MOTION-RM003O-EN-P - November 2023 Kinetix 6500, Fault S55 => (a) Improperly sized drive or motor, (b) Mechanical system out of specification. The servo controller is telling you that when it tries to move the load to the commands you have given it (i.e., position, velocity, acceleration, etc.), that it detects this cannot be achieved properly.It depends if you're running your drives through cip or not. The axis faults bits don't give you all the details. Look up cip axis faults in the help. It throws into a 64 but quad word and will give you description for all the bits. You can decode it based on what revision or drive you're using. 1. Literature Library | Rockwell Automation It depends if you're running your drives through cip or not. The axis faults bits don't give you all the details. Look up cip axis faults in the help. It throws into a 64 but quad word and will give you description for all the bits. You can decode it based on what revision or drive you're using. 1. Bipolar disorder may not be our fault, but it is our responsibility. Owning mistakes caused by bipolar symptoms on this podcast. We have probably done things we’re not proud of whi...You will use the Kinetix and ControlLogix workstations, containing real and simulated devices, to practice the tasks and concepts involved in maintaining and troubleshooting a Kinetix 6000 system. After learning maintenance and troubleshooting techniques, you will learn how to interpret Logix Designer projects for motion applications, understand fault …COUNT ERROR FAULT. FLT M26 – RUNTIME ERROR. (2) FLT M28 – SAFETY COMM. (1) Does not apply to induction motors in frequency control mode. (2) Applies to drives in Integrated STO mode. Table 119 - System Behavior, NODE FLT Fault Codes. Exception Fault Code. NODE FLT 01 – LATE CTRL UPDATE. When a fault is detected, the status indicator displays an E and a two-digit 6. Tighten the captive screw. Captive Screw (apply 1.1 N•m (10 lb•in) torque) IAM or AM Power Module (IAM power module is shown) Bulletin 2094 Control Module (Kinetix 6200 control module is shown) Repeat step 2 through step 5 to mount a control module onto each power module installed on your Bulletin 2094 power rail. Manual Indicated the following: Safe FLT 03...MP OUT NN. Motion Power Output Fault. A fault has been detected on the motion power output circuitry. On Safe Torque Off (-SO) models, the sub code is defined as follows: 01: Gate power evaluation fault. 02: Gate enable evaluation fault.Oct 13, 2017 · The system consists of a 1756-L73S Version 20 Processor and a 1756-EN2TR/B Version 5.28. The network has powerflex 40Ps and 1734-AENTRs on it. The Kinetix modules are 2094-EN02D-M01-SO Version 2.18. It has one rack with 4 Axis. There are 7 powerFlex 40ps and 7 1734-AENTR racks on the this system. Kinetix 6500 safe fault codes ... Kinetix 6200 and Kinetix 6500 . safe Torque-off Multi-axis Servo Drives Catalog Numbers 2094-SE02F-M00-S0, 2094-EN02D-M01-S0. Safety Reference Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment.The Kinetix® 6200 or Kinetix 6500 modular drives consist of an integrated axis (IAM) power module and up to seven axis (AM) power modules each coupled with a Kinetix 6200 or Kinetix 6500 control module. The IAM and AM power modules provide power for up to eight servo motors or actuators. Refer to the Kinetix 6200 and Kinetix 6500 Modular …Sep 6, 2020. #5. mike3475 said: trend axis torque feedback to see if there is a spike when physical axis fault happens, if so, change MAM or MCD instructions parameters to smooth the waveform.you can't completely eliminate the spike, just try to low its value as possible. Thanks for the assistance Mike.FLT S46…AUX FDBK COMM UL (Kinetix 6500 drives only) Aux Feedback Serial Comms. Table 81 - FLT Sxx Fault Codes (continued) Four-character Display Message. RSLogix 5000 Fault Message. Problem or Symptom. Potential Cause. Possible ResolutionThe fault history queue stores the fault codes and timestamps for the last 10 faults that occurred. Refer to the Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drive User Manual, publication 2094-UM002, for more information on accessing the drive web page. Page 35: Status Attributes This is not required for AxisCIPDrive.GuardStatus tags.AB Kinetix 6500 Drive Fault S55 01 . Hi All, I am used to working with Siemens drives but have a machine that is being ran with AB servo drives and motors and could use some help. ... Persistent P0507 (high idle) code after new throttle body and plenum spacerRead online or download PDF • Page 219 / 290 • Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual • Rockwell Automation Equipment ... FLT Mxx Fault Codes. Four-character Display Message. RSLogix 5000 Fault Message. Description. CIP Motion Exception Behavior. …Kinetix 6500, Fault S55 => (a) Improperly sized drive or motor, (b) Mechanical system out of specification. The servo controller is telling you that when it tries to move the load to the commands you have given it (i.e., position, velocity, acceleration, etc.), that it detects this cannot be achieved properly.Mounting hole dimensions for the Kinetix 350 drive are shown in the Kinetix 3, 300, 350, 2000, 6000, 6200, 6500, 7000 Servo Drives Specifications Technical Data, publication KNX-TD005. 2. Attach the Kinetix 350 drive to the cabinet, first by using the upper mounting slots of the drive and then the lower.Safety Reference Manual Kinetix 60 and Kinetix 6500 Safe Torque-off Multi-axis Servo Drives Catalog Numbers 94-SE02F-M00-S0, ... Fault Codes and Descriptions The drive web page can display a fault history queue, which provides a …Summary of Contents for Allen-Bradley ControlLogix. Page 1 Reference Manual Integrated Motion on the EtherNet/IP Network ControlLogix, CompactLogix, Kinetix 350, Kinetix 5500, Kinetix 5700, Kinetix 6500, PowerFlex 527, PowerFlex 755... Page 2 Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE).If you're feeling extra peevish, these common behaviors may be at fault. It’s normal and expected to be irritable sometimes—when we’re overly tired, when our environment is too lou...These enhancements correspond to Kinetix 6500 drive firmware revisions when used with RSLogix 5000 software. Table 1 - Enhancements with Revision 2.013. Cat. No. Enhancement. 2094-EN02D-M01-S0 and 2094-EN02D-M01-S1. The drive can detect reversed wiring of the encoder's sine and cosine signals when running a commutation test.Read online or download PDF • Page 126 / 156 • Rockwell Automation 2097-Vxxx Kinetix 350 Single-axis EtherNet/IP Servo Drive User Manual User Manual • Rockwell Automation Equipment. Manuals Directory ManualsDir.com - online owner manuals library. ... Table 58 - Drive Behavior, nFxx Node Fault Codes. Four-digit Display. Name. Description.Read online or download PDF • Page 126 / 156 • Rockwell Automation 2097-Vxxx Kinetix 350 Single-axis EtherNet/IP Servo Drive User Manual User Manual • Rockwell Automation Equipment. Manuals Directory ManualsDir.com - online owner manuals library. ... Table 58 - Drive Behavior, nFxx Node Fault Codes. Four-digit Display. Name. Description.Literature Library | Rockwell AutomationTroubleshooting the Kinetix 6200 and Kinetix 6500 Drive System. Chapter 8. Refer to the table on. ... Inhibit - Std. and Fault Code (5) INHIBIT Sxx. Refer to footnote ...Justifying an act of cheating could appear to be a moral low point—but in Bihar’s case, it needs to be done. Justifying an act of cheating could appear to be a moral low point—but ...Kinetix 6000 drives produce leakage current in the protective-earthing conductor that exceeds 3.5 mA AC and/or 10 mA DC. The minimum size of the protective-earthing (grounding) conductor used in the application must comply with local safety regulations for high protective-earthing conductor current equipment.Advertisement You can get the full story on earthquakes in How Earthquakes Work, but a review of the basics will help here. Earthquakes occur when masses of rock in Earth's crust s...Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual Page 205. ... Table 83 - INIT FLT Fault Codes. Four-character Display Message. RSLogix 5000 Fault Message. Problem or Symptom. Potential Cause. Possible Resolution.Fault Code and Type Returns 0 CORRECTED: CIP Message reads the Fault Code and Type and returns 0. Fault Code and Type now match values displayed on the Axis Properties\Fault and Alarm Log. Lgx00132375 Faults During 480V Loss Test CORRECTED: Drive sends ControlSyncFault and ModuleSyncFaults during 480V loss test in firmware revisions >1.042 ...Troubleshooting the Kinetix 6200 and Kinetix 6500 Drive System. Fault Codes. These fault code tables are designed to help you resolve anomalies. When a fault is detected, the four-character status indicator scrolls the display message. This is repeated until the fault code is cleared.These enhancements correspond to Kinetix 6500 drive firmware revisions when used with RSLogix 5000 software. Table 1 - Enhancements with Revision 2.013. Cat. No. Enhancement. 2094-EN02D-M01-S0 and 2094-EN02D-M01-S1. The drive can detect reversed wiring of the encoder's sine and cosine signals when running a commutation test.The Kinetix® 6200 or Kinetix 6500 modular drives consist of an integrated axis (IAM) power module and up to seven axis (AM) power modules each coupled with a Kinetix 6200 or Kinetix 6500 control module. The IAM and AM power modules provide power for up to eight servo motors or actuators. Refer to the Kinetix 6200 and Kinetix 6500 Modular … Literature Library | Rockwell Automation Oct 20, 2020 · This is my third attempt to post. My copy of the Kinetix 5500 manual has an Excel file attached to it that provides more information about the faults. I've tried to post a screenshot, but those posts didn't work, so I'll skip that step this time. Sign in with your organizational account. User Account. PasswordA study released today finds that big earthquakes around the world have triggered separate quakes in the US where wastewater resulting from natural gas production is injected under...User Manual Kinetix 6000 Multi-Axis Servo Drives.pdf. User Manual Kinetix 6000 Multi-Axis Servo Drives.pdf. Sign In. Details ...166. Rockwell Automation Publication 2094-UM001H-EN-P - June 2013. Chapter 7. Troubleshooting the Kinetix 6000 Drive System. E09. BusUndervoltage FaultSafety Function. This application monitors an emergency stop push button, using a safety relay. The safety outputs of the relay are connected to the dedicated safety inputs of the Kinetix 300 drive. If the emergency push button is triggered, the safety relay detects the condition and disables its two safety outputs.If it feels like you are unwanted at home, here's how to manage and create healthy ways to cope. Every child deserves parental love. If your parent emotionally neglects you, it’s n...Install the Kinetix 6000 Shunt Module. These procedures assume you have prepared your panel, mounted your Bulletin 2094 power rail, and understand how to bond your system. For installation instructions regarding equipment and accessories not included here, refer to the instructions that came with those products.GuardOKStatus CORRECTED: Modify the drive GuardOKStatus bit to behave the same as a Kinetix 6500 drive. Bit 0 of attribute 980, GuardOK, is now implemented. If safe guard is OK, this bit is set high. This bit is set 0, low, if any of the conditions exist for ... Fault Code and Type now match values displayed on the Axis Properties\Fault and ...Predicting Earthquakes - Predicting earthquakes is based on the movement of the earth's plates and fault zones. Read about predicting earthquakes and earthquake precautions. Advert... When a fault is detected, the status indicator displays an E and a two-digit Page 42 Chapter 2 Plan the Kinetix 6000 Drive System Installation Observe these guidelines when the 2094-AL09 or 2094-BL02 LIM module is used in the Bulletin 2094 system and mounted above the IAM module: • The clean zone (C) is to the right and beneath the Bulletin 2094 system (gray wireway).Do you know what to do after an accident that is not your fault? What about if you are at fault? Know your rights and responsibilities under the law. By clicking "TRY IT", I agree ...Quantum computing has been something of a holy grail in the world of technology: In theory, it promises an unprecedented amount of processing power that could be used to solve the ...A study released today finds that big earthquakes around the world have triggered separate quakes in the US where wastewater resulting from natural gas production is injected under...Though inkjet cartridge replacements are widely available, a growing number of consumers are avoiding costly cartridges and instead repeatedly refilling the ink in their old ones. ...Read online or download PDF • Page 202 / 290 • Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual • Rockwell Automation EquipmentPage 172: Fault Codes Chapter 9 Kinetix 5500 Safe Torque-off - Hardwired Safety Fault Codes For fault code descriptions and possible solutions, see the Kinetix 5500 Fault Codes.xlsx file attached to this publication. For more information about the file, see Access the Attachments page... Page 173: Probability Of Dangerous Failure Per HourSupport for Heidenhain EnDat 2.1 and 2.2 on third-party motors has been added. Kinetix 6500 Modular Multi-axis Servo Drives, Firmware Revisions 2.001...2.018 3. The drive’s absolute position feature tracks the position of the motor, within the multi-turn retention limits, while the drive is powered off.144. Rockwell Automation Publication 2198-UM001D-EN-P - May 2014. Chapter 7. Troubleshooting the Kinetix 5500 Drive System. Table 58 - INIT FLT Fault CodesSep 5, 2018. #1. Good afternoon to all, I have a 1756-EN2TR PLC using studio 5000, along with a Kinetix 6500 (2094-EN02D-M01-S0) drive. This drive controls my infeed of a grinding wheel. When I run at our normal production speed, the drive faults out and the machine gets thrown into e-stop due to Inhibit M05 fault.Kinetix 6000 Fault Codes. Thread starter P.BELL; Start date Jun 2, 2011; P.BELL Member. P. Join Date Jun 2011 Location Kings Lynn Posts 12. Jun 2, 2011 #1 I had a problem yesterday with a drive tripping, showing the code E04(MotorOvertemp Fault). Today the same motor is tripping with the code E19(PositionErrorFault). I run two …Additional Fault Codes. Description. 16#0001. Configuration revision number invalid Valid numbers are 0 or 1. 16#0002. Filter value invalid. 16#0003. RTS invalid. 16#0004. Pass-through handle timeout. 16#1001. Configuration does not match In a multiple owner setup, with the configuration revision number set to 1, the configurations must match. TIP.Kinetix 6500 fault code s44 DC bus voltage for 460V system is below 275V. • Verify voltage level of the incoming AC power. • Check AC power source for glitches or line drop. ... For information on troubleshooting SAFE FLT fault codes, refer to the Kinetix 6200 and Kinetix 6500 Safe Speed Monitoring Safety Reference Manual, publication 2094 ...S41, S43 & S44 Faults on Kinetix5700. Hi, I have a problem with a K5700 it is constantly faulting and stopping, I've checked the axis fault log and got this: Also I checked the servodrive fault log and got the faults S41, S43 & S44: The user manual describes this faults: This axis controls a linear motor, so with all your experience what do you ...Kinetix 6500 (2094) (Series A) 2.013. Kinetix 6500 Multi-axis Servo Drives; 2094-EN02D-M01-S0 & 2094-EN02D-M01-S1. Select Files Firmware Only ...Literature Library | Rockwell AutomationKinetix 6500 fault codes m07. Kinetix 6000 fault code 4. Our technical director, Justin Jewett summed it up excellently when he said: Â"We need fewer murderers and more¹ street fighters.Â" Jewett points out that we need people who can quickly program, handle fists and do the best job possible â which is particularly difficult when things ...1. Check Drive Status - Refer to Table Below Kinetix 6000 Troubleshooting IAM/AM Seven-Segment Status LED Status Do This Actively cycling (phase 0) The drive is looking for…Fault Codes and Descriptions. The drive web page can display a fault history queue, which provides a record of . the faults detected by the drive. The fault history queue stores the fault codes and . timestamps for the last 10 faults that occurred. Refer to the Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drive . User Manual, publicat ... Kinetix 6500 (2094) (Series A) 2.013. Kinetix 6500 Multi-axis Servo Drives; 2094-EN02D-M01-S0 & 2094-EN02D-M01-S1. Select Files Firmware Only ... Read online or download PDF • Page 197 / 290 • Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual • Rockwell Automation Equipment ... Initialization Fault - Std. and Fault Code (5) INIT FLT Sxx. X1:INIT FLT Sxx. X2:INIT FLT Sxx. 3. 4 (6) Initialization Fault - Mfg ...

The functional issue described above has been corrected in the following versions of the Kinetix 6000 Multi-Axis Servo Drive with manufacturing date codes of 4306 and subsequent: • 2094-BC01-Mxx, 2094-BC01-Mxx-S, 2094-BC02-M02, 2094-BC02-M02-S, 2094-BMP5, 2094-BMP5-S, 2094-BM01, 2094-BM01-S, 2094-BM02, 2094-BM02-S.. Kittens for sale clarksville tn

kinetix 6500 fault codes

Kinetix 6500 safe fault codes ... Kinetix 6200 and Kinetix 6500 . safe Torque-off Multi-axis Servo Drives Catalog Numbers 2094-SE02F-M00-S0, 2094-EN02D-M01-S0. Safety Reference Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment.Fault Codes and Descriptions. The drive web page can display a fault history queue, which provides a record of . the faults detected by the drive. The fault history queue stores the fault codes and . timestamps for the last 10 faults that occurred. Refer to the Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drive . User Manual, publicat ...After two years of trial, Abdulrasheed Maina was convicted and given an eight-year sentence for pension fraud in Nigeria. Abdulrasheed Maina, a former Nigerian government official ...Support for Heidenhain EnDat 2.1 and 2.2 on third-party motors has been added. Kinetix 6500 Modular Multi-axis Servo Drives, Firmware Revisions 2.001...2.018 3. The drive’s absolute position feature tracks the position of the motor, within the multi-turn retention limits, while the drive is powered off.144. Rockwell Automation Publication 2198-UM001D-EN-P - May 2014. Chapter 7. Troubleshooting the Kinetix 5500 Drive System. Table 58 - INIT FLT Fault CodesThe fault history queue stores the fault codes and timestamps for the last 10 faults that occurred. Refer to the Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drive User Manual, publication 2094-UM002, for more information on accessing the drive web page. Page 35: Status Attributes This is not required for AxisCIPDrive.GuardStatus tags.Mounting hole dimensions for the Kinetix 350 drive are shown in the Kinetix 3, 300, 350, 2000, 6000, 6200, 6500, 7000 Servo Drives Specifications Technical Data, publication KNX-TD005. 2. Attach the Kinetix 350 drive to the cabinet, first by using the upper mounting slots of the drive and then the lower.Rockwell Automation Publication 2094-UM001H-EN-P - June 2013. 165. Troubleshooting the Kinetix 6000 Drive System. Chapter 7. Kinetix 6000 Drive System Error CodesKinetix 6500 fault codes December 17th, 2016, 03:44 PM #1 Member Join Date: Feb 2013 Location: Serbia Posts: 38 Kinetix 6500 Allen Bradley Hello everyone, I have a problem with variable drive. 6. Tighten the captive screw. Captive Screw (apply 1.1 N•m (10 lb•in) torque) IAM or AM Power Module (IAM power module is shown) Bulletin 2094 Control Module (Kinetix 6200 control module is shown) Repeat step 2 through step 5 to mount a control module onto each power module installed on your Bulletin 2094 power rail. troubleshooting safety applications that use the Kinetix 6200 and Kinetix 6500 drives with safe speed monitoring. You must have a basic understanding of electrical circuitry and familiarity with Kinetix 6200 and Kinetix 6500 drives. You must also be trained and experienced in the creation, operation, and maintenance of safety systems.The system consists of a 1756-L73S Version 20 Processor and a 1756-EN2TR/B Version 5.28. The network has powerflex 40Ps and 1734-AENTRs on it. The Kinetix modules are 2094-EN02D-M01-SO Version 2.18. It has one rack with 4 Axis. There are 7 powerFlex 40ps and 7 1734-AENTR racks on the this system.Kinetix 5700 Fault Codes - Free download as Excel Spreadsheet (.xls / .xlsx), PDF File (.pdf), Text File (.txt) or read online for free. Kinetix 5700 Fault Codes.